>> Back to Concrete Testing Index <<
US Testing Company, Inc. Water Vapor Transmission Test
Concrete Treat: Concrete Blanket & Sealer Results
Report No.: EN94-0162.1
Revised: 8/11/94
Revision of: CM93-0131.1R
Issued: 10/25/93
SUBJECT: Water Vapor Transmisson Test.
MATERIAL EVALUATED:
Concrete Treat: Concrete Blanket and Sealer
TEST PROCEDURE:
This material was tested for permanence in accordance with ASTM E 96 (Dry Desiccant Method).
RESULTS:
Specimen |
Water Vapor Tramsmission (grains/hr-ft²) |
Permeance (perms) |
1 |
< 0.04 |
< 0.102 |
2 |
< 0.04 |
< 0.102 |
Average |
< 0.04 |
< 0.102 |
| Material Thickness | 0.85 |
| Average Test Temperature | 72 |
| Relative Humidity | 51 |
Tested By:
David A. Trezza, Engineer
Robert C. Smith, M. Sc., P.E. - Tulsa Branch Manager